Biosafety Cabinet Class 2 (Product Code: SLE/LI/10) is a Class II A2 biological safety cabinet used to protect laboratory staff, the environment and sensitive work processes when biological agents are handled in microbiology, biotechnology and research laboratories. Its welded white polypropylene body with a stainless steel 304 worktop is easy to clean, and two HEPA filters with a 70% downflow / 30% exhaust airflow pattern provide contamination protection. This bio safety cabinet is supplied by Jain Scientific Equipments Pvt Ltd (ScienceLab), Ambala, India.
| Parameter | Detail |
|---|---|
| Cabinet type | Class II A2 biological safety cabinet |
| Outer dimensions (W x D x H) | 1220 x 800 x 1500 mm (48 x 31.5 x 59 in) |
| Inner dimensions (W x D x H) | 1135 x 600 x 640 mm (44.7 x 23.6 x 25.2 in) |
| Cabinet material | Welded white polypropylene structure with stainless steel 304 worktop |
| Filtration | Two HEPA filters, typical efficiency 99.9995% at 0.1 µm; HEPA/ULPA filters listed |
| Airflow pattern | 70% downflow (circulation), 30% exhaust |
| Downflow velocity | 0.45 m/s (90 fpm) |
| Inflow velocity | 0.5 m/s (100 fpm) |
| Front sash opening | 450 mm (17.7 in) |
| Noise level | Below 52 dB |
| Illumination | 800 lux, LED lighting |
| Fan | EC fan motor |
| Control system | Touch-screen control with alerts for periodic maintenance and device replacement |
| Energy saving | Programmable night mode that shuts down unnecessary consumption and holds vital components at the required safety level |
| Power supply | 230 V, 60 Hz, single phase |
| Product code | SLE/LI/10 |
| Supplied by | Jain Scientific Equipments Pvt Ltd (ScienceLab), Ambala, India |
A Class II biosafety cabinet is used for handling microbial cultures, cell lines and other biological material when the operator, the room and the sample all need protection. Air drawn in at the front opening keeps aerosols away from the operator, filtered downflow keeps the work surface clean, and filtered exhaust protects the room. Typical tasks in microbiology lab equipment set-ups include pouring and inoculating plates, subculturing and preparing samples.
Switch the cabinet on and let the airflow settle before starting, keep the front grille clear and work well inside the opening. Load only what the task needs, wipe the stainless steel worktop before and after each session, and act on the touch-screen alerts so filters and devices are replaced when due. The night mode reduces electricity use between sessions.
ScienceLab is the trading name of Jain Scientific Equipments Private Limited, which supplies this Class II A2 cabinet from Ambala, Haryana, to universities, research institutes, colleges, dealers and importers. Room layout, mains supply and filter choice differ between laboratories, so these points are worth settling with us before a quotation is prepared. More about the company is on our company profile.
Equipment that fits the same culture-handling workflow:
See all items in Laboratory Instruments.
What class is the Biosafety Cabinet Class 2?
The Biosafety Cabinet Class 2 is a Class II A2 biological safety cabinet. It uses two HEPA filters and a 70% downflow, 30% exhaust airflow pattern to protect the operator, the laboratory environment and the work inside the cabinet.
What are the dimensions of the Class 2 biosafety cabinet?
The Biosafety Cabinet Class 2 measures 1220 x 800 x 1500 mm outside (W x D x H) and gives a 1135 x 600 x 640 mm work zone inside. The front sash opening is 450 mm, so check doorways and room space before ordering.
What filters does the biosafety cabinet use?
The Biosafety Cabinet Class 2 uses two HEPA filters with a typical efficiency of 99.9995% at 0.1 µm, and HEPA/ULPA filtration is listed. Its touch-screen control system alerts users when periodic maintenance and device replacement are due.
What power supply does the Biosafety Cabinet Class 2 need?
The Biosafety Cabinet Class 2 is listed for 230 V, 60 Hz, single-phase power. Its LED lighting and EC fan motor are low-energy parts, and a programmable night mode cuts unnecessary consumption. Confirm your local mains supply with us before ordering.
Who supplies the Biosafety Cabinet Class 2?
The Biosafety Cabinet Class 2 is supplied by Jain Scientific Equipments Pvt Ltd (ScienceLab), Ambala, Haryana, India, to research institutes, universities, colleges, dealers and importers in India and international markets.
Is a calibration certificate or airflow report available with the cabinet?
Documentation for the Biosafety Cabinet Class 2, such as a calibration certificate or airflow report, should be discussed with us before ordering. We will confirm what accompanies the unit you are quoted; please raise it through our contact page.
What should a quotation request for the biosafety cabinet include?
A quotation request for the Biosafety Cabinet Class 2 should state the quantity, your mains supply, room and doorway sizes, any spare filters required and the delivery location. Sending these details together helps the quotation match your site.
Request a quotation for the Biosafety Cabinet Class 2 through our contact page, or add it to the enquiry cart with other microbiology and laboratory items you plan to order.