This aluminium calorimeter is a plain cup that holds water or another liquid in method-of-mixtures practicals, where a heated solid is lowered in and the temperature change is measured. It is 75 mm long and 50 mm in diameter, with parallel sides and a rolled rim. The cup takes part in the heat exchange, so its mass goes into the calculation. It is supplied without a stirrer.
| Parameter | Detail |
|---|---|
| Material | Aluminium |
| Form | Parallel sides with rolled rim |
| Length | 75 mm |
| Diameter | 50 mm |
| Stirrer | Not included |
| Product code | SLE/PHY/143 |
| Minimum order | 10 units |
| Dispatch | Usually within 7 to 10 working days |
| Manufacturer | ScienceLab (Jain Scientific Equipments Pvt Ltd), Ambala, India |
Specific heat of a solid by mixtures. Weigh the dry cup on an electronic balance, half fill it with cold water and weigh it again. Heat one of the metal cylinders in boiling water in a glass beaker until its temperature is steady. Lower it into the cup, stir, and note the highest steady reading. Heat lost by the metal equals heat gained by the water and the cup.
Comparing metals. Repeat the run with the other cylinders of the set, weighing each one first. Keep the starting water temperature close to room temperature each time. Stand the cup in calorimeter lagging for every run, so that the values found for different metals can be compared fairly.
Latent heat of fusion of ice. Warm the water in the cup a few degrees above room temperature and read it with an immersion thermometer. Add small pieces of ice dried on filter paper, stir until they melt, and note the minimum reading. Weigh again to find the mass of ice. The heat given up by the water and cup, minus the heat that warmed the melted ice, divided by that mass, gives the latent heat.
The cup warms up with the water, so it takes a share of the heat given out by the hot sample. Its mass times the specific heat of aluminium gives the heat it absorbs per degree. Leave it out of the heat balance and the result for the sample comes out too low.
Lift it out of the boiling water and lower it into the cup in one quick, smooth movement. Let the drips fall back into the beaker first, because hot water carried across adds heat that the sample did not give. Lower it gently so no water splashes out of the cup.
Stir gently and watch the thermometer. The reading climbs, levels off and then begins to fall slowly as the cup loses heat to the room. Record the highest steady value. At that point the sample, the water and the cup have reached thermal equilibrium.
Heat escapes from the cup walls, the rim and the water surface while the temperatures even out, so the water rises less than it should. A lid, lagging around the cup and a fast transfer all reduce the loss. Reading the thermometer before the mixture settles also gives a low value.
Water next to the hot sample warms first while water near the wall stays cooler. Stirring brings it all to one temperature, so the thermometer bulb reads the true average. The cup comes without a stirrer, so use a separate one and move it gently up and down.
Aluminium conducts heat well, so the cup quickly reaches the same temperature as the water inside it. It is a light metal, so the cup adds little mass. Its specific heat is high for a metal, so the cup's share of the heat is noticeable and must be included in the heat balance.