The Dual Range Ammeter is a moving-coil meter for direct current. It reads two ranges, 0–1 A and 0–5 A, on one 60 mm scale, so the same meter serves small student circuits and higher-current work. It has 4 mm sockets and a zero adjustment.
| Parameter | Detail |
|---|---|
| Meter type | Moving-coil ammeter, DC only |
| Current ranges | 0–1 A and 0–5 A |
| Scale | Single 60 mm scale for both ranges |
| Accuracy | 2.5% |
| Overall size | 125 × 80 × 80 mm |
| Connections | 4 mm socket terminals |
| Zero adjustment | Yes |
| Product code | SLE/PHY/01A |
| Minimum order | 10 units |
| Dispatch | Usually within 7 to 10 working days |
| Manufacturer | ScienceLab (Jain Scientific Equipments Pvt Ltd), Ambala, India |
Ohm's law. Connect the ammeter in series with a resistance wire, a rheostat, a one way key and a stepped power supply, with a voltmeter across the wire. Change the rheostat setting, record pairs of current and voltage, and plot the graph.
Series and parallel lamps. Wire two lamps in MES bulb holders, first in series and then in parallel, using crocodile clips and leads. Move the ammeter into each branch and then into the main line to show that the branch currents add up to the total.
Electrolysis of copper sulphate. Place the ammeter in series with a copper voltameter and hold the current steady with the rheostat. Weigh the cathode before and after a timed run and compare the mass of copper deposited with the charge passed.
It measures the current that passes through it, so the circuit current must flow through the meter. Its resistance is very low, so placing it across a component or the supply would short the circuit and could damage the movement.
Start on the 0–5 A range when the current is unknown. If the reading stays below 1 A, switch off, change to the 0–1 A range and switch on again. The pointer then moves further across the scale and is easier to read.
A moving-coil meter reads current in one direction only. Connected backwards, the pointer is pushed below zero against its stop. Switch off at once and swap the leads so that current enters at the positive terminal.
Slightly. The meter adds its own small resistance to the circuit, so the current falls a little when it is inserted. In most school circuits this loading effect is small compared with the readings taken.
No. It is a moving-coil meter for direct current only. For AC circuits, use a meter that is rated for alternating current.
With the meter disconnected, look at the pointer straight on rather than from an angle. Turn the zero adjustment until the pointer rests exactly on zero, and repeat the check if the meter has been moved.
To request a quotation, send the product name, code and quantity through our contact page or add the item to your enquiry cart.