Electrosurgical Unit w/access

Product Code : SLE/HE/07

Electrosurgical Unit w/access (Product Code: SLE/HE/07) is a microprocessor-controlled electrosurgical generator used to cut tissue and coagulate bleeding during major and minor general surgery in hospital operating theatres. It offers mono-polar CUT and COAG modes plus bi-polar COAG at an output frequency of 330–430 kHz, and it stands on a cart with a double-function foot switch. It is supplied by Jain Scientific Equipments Pvt Ltd (ScienceLab), Ambala, India.

Specifications

ParameterDetail
ApplicationGeneral surgery, including major and minor procedures
GeneratorMicroprocessor controlled; automatic self-test
OutputsMono-polar and bi-polar
CUT mono-polarUp to 300 W at 500 ohm / 200 W at 300 ohm, depending on the available model; modes at least pure, blend and hemostasis
COAG mono-polarUp to 120 W / 200 W, depending on the available model; modes at least contact/standard, soft, forced and spray
COAG bi-polarUp to 50 W / 120 W, depending on the available model
Output frequency330–430 kHz
Power settingAdjustable, with pre-set programs and user-defined procedures
Return electrode monitoringFor mono-polar use: automatic monitoring of patient connection; generator stops on bad or lost connection
DisplayFront display/control panel with working parameters, settings, alarms and errors
ControlsDouble-function foot switch for mono- and bi-polar output (CUT yellow and COAG blue pedals); hand switch controls, at least for mono-polar
CompatibilityCommercial cables and electrodes
Cart4 anti-static swivel castors (2 with brakes), a drawer and storage for the foot switch
Power supply220 V / 50 Hz
Power consumption500–700 W
Product codeSLE/HE/07
Supplied byJain Scientific Equipments Pvt Ltd (ScienceLab), Ambala, India

What Is the Electrosurgical Unit Used For?

Surgeons use an electrosurgical unit to cut tissue and seal bleeding vessels with high-frequency current, rather than relying only on a scalpel and ties. In mono-polar work the current flows from the active electrode through the patient to the return electrode, while in bi-polar work it passes only between the two tips of the forceps, which suits fine coagulation close to delicate structures.

Before surgery, the theatre team places and checks the return electrode, selects a CUT or COAG mode and power level on the front panel or recalls a pre-set program, and lets the unit run its automatic self-test. During the operation the surgeon works from the yellow CUT and blue COAG pedals or from the hand switch. Only staff trained in electrosurgery should operate the unit.

What to Specify When Ordering

  • The power model you need – listed CUT outputs are up to 300 W at 500 ohm or 200 W at 300 ohm, depending on the model.
  • Confirmation that the theatre supply is 220 V / 50 Hz.
  • Which electrodes and cables you want quoted, bearing in mind that the unit accepts commercial cables and electrodes.
  • The number of units, for example one per operating theatre.

Supplier

Jain Scientific Equipments Private Limited, which operates under the ScienceLab name, supplies this electrosurgical unit from Ambala, Haryana, to hospitals, surgical training centres and public health programmes. Theatre fit-outs can be quoted as a package, with the generator alongside operating lights, tables and suction pumps. Company details are on our about ScienceLab page.

Related Resuscitation & Operating Theatre Equipment

Operating theatres equipping for electrosurgery often order:

The complete range is in the Resuscitation & Operating Theatre Equipment category.

Frequently Asked Questions

What output power does the Electrosurgical Unit w/access provide?
Depending on the available model, the Electrosurgical Unit w/access gives mono-polar CUT up to 300 W at 500 ohm or 200 W at 300 ohm, mono-polar COAG up to 120 W or 200 W, and bi-polar COAG up to 50 W or 120 W.

Which modes does the Electrosurgical Unit w/access offer?
The Electrosurgical Unit w/access offers mono-polar CUT with at least pure, blend and hemostasis modes, mono-polar COAG with at least contact/standard, soft, forced and spray modes, and bi-polar COAG. Power is adjustable, with pre-set programs and user-defined procedures.

Does the Electrosurgical Unit w/access monitor the return electrode?
Yes. For mono-polar use the Electrosurgical Unit w/access has a return electrode safety system that automatically monitors the patient connection and stops the generator if the connection is poor or lost. It also runs an automatic self-test and shows alarms and errors on the front panel.

Will the Electrosurgical Unit w/access work with our existing electrodes?
The Electrosurgical Unit w/access is described as compatible with commercial cables and electrodes. Tell us the brands and connector types you already use when you ask for a quotation, so the match can be checked before supply.

What power supply does the Electrosurgical Unit w/access need?
The Electrosurgical Unit w/access runs on 220 V / 50 Hz mains and consumes 500–700 W. It stands on a cart with four anti-static swivel castors, two with brakes, plus a drawer and storage for the foot switch.

Can test or calibration documents be provided?
Output test reports or calibration documents for the Electrosurgical Unit w/access are not listed as standard. If your hospital needs them for acceptance, raise it through the contact page before ordering so we can tell you what documentation is available.

Who supplies the Electrosurgical Unit w/access?
Jain Scientific Equipments Pvt Ltd (ScienceLab), Ambala, Haryana, India, supplies the Electrosurgical Unit w/access to hospitals, surgical centres, health programmes and medical equipment dealers in India and international markets.

Request a Quote

Request a quotation for the Electrosurgical Unit w/access through our contact page, stating the model power and the accessories you need, or add the unit to the enquiry cart with your other theatre equipment.

Last updated: 24 September 2026

Request A Catalogue

Request A Cataloguer

Request Now for a Catalogue and Get best deals for your Products

Request Now
Supply of Electrosurgical Unit w/access from India to Finland, France, Tanzania, Thailand, Sri Lanka, Congo, Costa Rica, Ivory Coast, Croatia, Cuba, Cyprus, Czech Republic, Denmark, Djibouti, Dominica, Afghanistan, Albania, Algeria, Andorra, Angola, Antigua and Barbuda, Argentina, Armenia, Australia, Austria, Azerbaijan, Bahamas, Bahrain, Bangladesh, Barbados, United Arab Emirates (UAE, Dubai), United Kingdom (London), United States, Uruguay, Uzbekistan, Vanuatu, Belarus, Belgium, Belize, Benin, Bhutan, Bolivia, Bosnia and Herzegovina, Botswana, Brazil, Brunei, Bulgaria, Burkina Faso, Burma Myanmar, East Timor, Ecuador, Egypt, El Salvador, Equatorial Guinea, Eritrea, Estonia, Ethiopia (Addis Ababa), Fiji, Burundi, Cambodia, Cameroon, Canada, Cape Verde, Central African Republic, Chad, Chile, Colombia. Math Teaching Kit suppliers in Luxembourg, Macedonia, Madagascar, Malawi (Lilongwe), Malaysia (Kuala Lumpur), Maldives, Mali, Malta, Marshall Islands, Mauritania, Mexico, Micronesia, Moldova, Monaco, Mongolia, Montenegro, Morocco, Mozambique, Namibia, Comoros, Congo. Math Teaching Kit manufacturers in Dominican Republic, Gabon, Gambia, Georgia, Germany, Ghana, Greece, Grenada, Guatemala, Guinea, Guinea-Bissau, Guyana, Haiti, Honduras, Hungary, Iceland, Indonesia, Iran, Iraq, Niger, Nigeria (Abuja), Norway, Oman, Palau, Panama, Papua New Guinea, Paraguay, Peru, Philippines (Manila), Poland, Ireland, Israel, Italy, Jamaica, Japan, Jordan, Kazakhstan, Kenya (Nairobi), Kiribati, Korea, Kuwait, Kyrgyzstan, Laos, Latvia, Lebanon, Lesotho, Liberia, Liechtenstein, Lithuania, Mauritius, Nauru, Nepal, Netherlands, New Zealand, Nicaragua, Portugal, Qatar, Romania, Russia, Rwanda (Kigali). Math Teaching Kit exportets to Saint Kitts and Nevis, Saint Lucia, Saint Vincent and the Grenadines, Samoa, San Marino, Sao Tome and Principe, Saudi Arabia, Senegal, Serbia, Seychelles, Sierra Leone, Singapore, Slovakia, Slovenia, Solomon Islands, Somalia, South Africa, South Sudan, Spain, Sudan, Suriname, Swaziland, Sweden, Switzerland, Syria, Tajikistan, Togo, Tonga, Trinidad and Tobago, Tunisia, Turkey, Turkmenistan, Tuvalu, Uganda (Kampala), Ukraine, Venezuela, Vietnam, Yemen , Zambia (Lusaka), Zimbabwe