Computerized Cooling Tower Test Bench (Product Code: SLE/MCE/83) is a fan-driven cooling tower model used to study the evaporative cooling of water by air in thermal and chemical engineering laboratories. Colleges add this engineering lab equipment because its 150 × 150 mm cooling column holds a wet deck with a specific surface of 110 m²/m³, and a three-stage heater (500, 1000 or 1500 W) sets the heat load. It is made by Jain Scientific Equipments Pvt Ltd (ScienceLab), an OEM manufacturer, at its own factory in Ambala, India.
| Parameter | Detail |
|---|---|
| Cooling column cross-section | 150 × 150 mm |
| Wet deck specific surface | 110 m²/m³ |
| Airflow measurement | Volumetric airflow via orifice, Ø 80 mm |
| Heater | Adjustable in three stages: 500 W, 1000 W, 1500 W |
| Thermostat | Switches off at 50 °C |
| Fan | Power consumption 250 W; max. pressure difference 430 Pa; max. volumetric flow rate 13 m³/min |
| Pump | Max. head 70 m; max. flow rate 100 L/h |
| Tank for additional water | 4.2 L |
| Measuring range – differential pressure (air) | 0–1000 Pa |
| Measuring range – flow rate (water) | 12–360 L/h |
| Measuring range – temperature | 2 × 0–50 °C and 3 × 0–100 °C |
| Measuring range – relative humidity | 10–100% |
| Dimensions | 1200 × 600 × 1600 mm |
| Weight | Approx. 125 kg |
| Power supply options | 230 V, 50 Hz, 1 phase or 230 V, 60 Hz, 1 phase |
| Product code | SLE/MCE/83 |
| Manufacturer | Jain Scientific Equipments Pvt Ltd (ScienceLab) — OEM |
| Country of origin | India (made in Ambala, Haryana) |
Warm water from the heated circuit is pumped to the column and spreads over the wet deck while air from the fan passes through it; part of the water evaporates and cools the rest. By measuring water and air temperatures, relative humidity, water flow and airflow through the 80 mm orifice, students calculate the cooling range, the approach to wet-bulb temperature, the heat removed and the water lost by evaporation.
Switching the heater between 500, 1000 and 1500 W and changing air and water flows shows how heat load and air-to-water ratio affect performance — the same questions faced in power-station and HVAC cooling towers. Keep the 4.2 L additional-water tank topped up, since evaporated water must be replaced, and remember that the thermostat switches the heater off at 50 °C.
Jain Scientific Equipments Private Limited, the legal company behind the ScienceLab brand, is the OEM of the Computerized Cooling Tower Test Bench. Each bench is manufactured at the company’s own licensed factory in Saha, Ambala, Haryana, India, and delivered factory-direct to engineering colleges, polytechnics, dealers and importers.
If you later need wet-deck packing, a spare pump or another bench, ask us — enquiries go straight to the manufacturer. More on the company is on the ScienceLab profile.
Cooling and humid-air practicals often extend to these units:
The Thermodynamics & Heat Transfer Lab Equipment category includes the full range of thermal trainers.
What is the wet deck specification of the Computerized Cooling Tower Test Bench?
The Computerized Cooling Tower Test Bench has a cooling column of 150 × 150 mm cross-section whose wet deck offers a specific surface of 110 m²/m³, giving a large contact area between the water and the air.
How is heat load varied on the Computerized Cooling Tower Test Bench?
Heat load on the Computerized Cooling Tower Test Bench is set with a heater adjustable in three stages of 500 W, 1000 W and 1500 W; a thermostat switches it off at 50 °C.
What do the fan and pump of the Computerized Cooling Tower Test Bench deliver?
The fan of the Computerized Cooling Tower Test Bench consumes 250 W, with a maximum volumetric flow of 13 m³/min and a maximum pressure difference of 430 Pa; the pump offers a maximum head of 70 m and a maximum flow of 100 L/h.
What are the measuring ranges of the Computerized Cooling Tower Test Bench?
The Computerized Cooling Tower Test Bench measures air differential pressure 0–1000 Pa, water flow 12–360 L/h, temperature with two sensors at 0–50 °C and three at 0–100 °C, and relative humidity 10–100%.
Who manufactures the Computerized Cooling Tower Test Bench?
The Computerized Cooling Tower Test Bench is manufactured by Jain Scientific Equipments Pvt Ltd (ScienceLab) as the OEM at its own factory in Ambala, Haryana, India. Quotations and spares enquiries are answered directly by the maker.
How is data logged on the Computerized Cooling Tower Test Bench?
Please confirm the data-logging arrangement of the Computerized Cooling Tower Test Bench with us before ordering, as the listed specification covers its sensors and measuring ranges; tell us whether you need PC recording via the contact page.
How much space does the Computerized Cooling Tower Test Bench need?
The Computerized Cooling Tower Test Bench measures 1200 × 600 × 1600 mm and weighs about 125 kg, so check door widths and floor space, and provide water filling and draining near the installation point.
Request a quotation for the Computerized Cooling Tower Test Bench through our contact page, or add it to the enquiry cart alongside other thermal trainers. The manufacturer quotes you directly.
Last updated: 24 September 2026